The T2 sensor can be combined with MB boards to be placed on the water supply pipe upstream 3 way valves
(not to be used with 2 way valve).
The T2 sensor must be used as described below:
- Change-Over for 2-pipe system for the automatic switch of the operating mode.
T2 9025310
T2 accessory for units with MB electronic board
A group of Climmy TopLine MB can be connected via a serial link and can consequently be managed at the same time
by just one T-MB wall mounted control or RT03 infra-red remote control. Using the special jumper present on
the MB board, one unit must be configured as the master, and all the others as slaves. It is clear that the remote
control must be pointed at the receiver on the master unit. To avoid problems, it is recommended to install and
connect the receiver only on the master unit.
With RT03 infra-red remote control
One control for each cassette One control for more cassettes (20 units max.)
(
= 800 m)
With T
-
MB wall mounted control
One control for each cassette
(
= 20 m)
One control for more cassettes (20 units max.)
(
= 800 m)
MB controls
TopLine /TopLine ECM
If water temperature is lower than 20°C, cooling mode is set; on the other hand, if water temperature exceeds 30°C,
heating mode is set.
-
It can be used on units with electric heater and hot water supply. The T2 priority probe activates the electric heater
or water valve, depending on the water temperature detected. If water temperature exceeds 34°C, the water valve
ON-OFF control is activated; on the other hand, if water temperature is lower than 30°C, the electric heater is
activated.