710
500
320
880
610
430
1500
970
710
1820
1280
710
279
226
165
315
255
205
720
541
441
824
651
441
1,62
1,32
0,96
1,83
1,48
1,19
4,18
3,14
2,56
4,79
3,79
2,56
139
113
83
156
127
103
493
365
291
569
449
291
1,61
1,32
0,97
1,82
1,48
1,20
4,33
3,27
2,67
6,61
5,22
3,39
213
173
127
241
195
157
554
416
340
633
501
340
2,48
2,01
1,47
2,80
2,27
1,83
6,44
4,84
3,95
7,36
5,83
3,95
288
233
170
326
263
212
736
552
450
843
666
450
3,35
2,71
1,98
3,79
3,06
2,46
8,56
6,42
5,23
9,80
7,74
5,23
363
294
214
411
332
266
919
689
561
1053
831
561
4,22
3,42
2,49
4,78
3,86
3,10
10,69
8,01
6,52
12,24
9,66
6,52
High
Med
Low
High
Med
Low
High
Med
Low
High
Med
Low
Model Speed
Air
flow
EWT 45 - LWT 40°C EWT 50 - LWT 40°C EWT 60 - LWT 50°C EWT 70 - LWT 60°C EWT 80 - LWT 70°C
l/hm
3
/h kW l/h kW l/h kW l/h kW l/h kW
Water
flow
Emission
Water
flow
Emission
Water
flow
Emission
Water
flow
Emission
Water
flow
Emission
710
500
320
880
610
430
1500
970
710
1820
1280
710
812
629
425
940
729
557
1804
1291
1012
2105
1607
1012
4,72
3,66
2,47
5,46
4,24
3,24
10,49
7,50
5,89
12,24
9,34
5,89
3,29
2,51
1,66
3,86
2,93
2,21
7,25
5,08
3,94
8,57
6,41
3,94
676
526
359
779
607
468
1508
1089
858
1754
1348
858
3,93
3,06
2,09
4,53
3,53
2,72
8,77
6,33
4,99
10,20
7,84
4,99
2,95
2,24
1,49
3,46
2,62
1,97
6,49
4,55
3,53
7,68
5,73
3,53
528
415
287
606
477
370
1189
867
689
1375
1066
689
3,07
2,41
1,67
3,52
2,77
2,15
6,91
5,04
4,00
7,99
6,20
4,00
2,60
1,97
1,31
3,05
2,31
1,73
5,72
4,00
3,10
6,77
5,05
3,10
378
288
192
442
337
256
836
587
459
987
739
459
2,20
1,67
1,12
2,57
1,96
1,49
4,86
3,41
2,67
5,74
4,30
2,67
2,20
1,67
1,12
2,57
1,96
1,49
4,86
3,41
2,67
5,74
4,30
2,67
High
Med
Low
High
Med
Low
High
Med
Low
High
Med
Low
EWT 5 - LWT 10°C EWT 7 - LWT 12°C EWT 9 - LWT 14°C EWT 12 - LWT 17°C
Water
flow
Total
emission
Sensible
emission
Water
flow
Total
emission
Sensible
emission
Water
flow
Total
emission
Sensible
emission
Water
flow
Total
emission
Sensible
emission
Model Speed
Air
flow
l/h kW kW l/h kW kW l/h kW kW l/h kW kWm
3
/h
Cooling emission of 2 battery units (4 pipe installation)
Entering air temperature: +27°C d.b. +19°C w.b.
Heating emission of 2 battery units (4 pipe installation)
Entering air temperature: +20°C
7/12 °C
10/15 °C
14/18 °C
K
K
K
0,9
0,72
0,5
0,94
0,78
0,58
1,06
0,9
0,72
7/12 °C
10/15 °C
14/18 °C
K
K
K
0,82
0,56
0,35
0,89
0,63
0,41
1,11
0,82
0,52
Water (°C) Air (°C) 25-18
26-18.5
28-20 Water (°C) Air (°C) 25-18
26-18.5
28-20
Total emission Sensible emission
Emission of 4 pipe units
with enhanced cooling battery
Note:
the correction
factors are indicative,
as they are
average values.
Emission correction factors for different working conditions.
Multiply the factors by the emission figures in the 7-12°C table above.
TL 3
.
6T
TL 5
.
6T
TL 6
.
6T
TL 2
.
6T
TL 3
.
6T
TL 5
.
6T
TL 6
.
6T
TL 2
.
6T
7